Quadcept DesignConverter : CR-5000 Board Designer Conversion
Import Settings
The following will explain the import settings of Quadcept DesignConverter.
Footprint Conversion
Item | Description |
Delete the assembly area of the component height 0 |
Enable this option to delete an assembly area with a component height of 0mm when running the conversion. * It is recommended to enable this option as an assembly area will be automatically generated in Quadcept. |
Convert the top English letter of the component name into a reference |
The initial letter of a component name will be converted into a reference when converting footprints. |
Text Settings |
Click this button to configure the text options. See the Text Settings section for details. |
Text Settings
Text Settings Dialog
Item | Description |
Reference Character Settings |
Use this region to define the properties for reference texts (Font, Line Width, Size, Space and Origin Point). |
Double Byte Character Settings |
When the double byte character exists in data, its font is able to be specified. |
PCB Conversion
Item | Description |
Delete the assembly area of the component height 0 |
Enable this option to delete an assembly area with a component height of 0mm when running the conversion. |
Convert Footprint as Component |
Enable this option to import the footprints on the design as components. |
Font of the double byte character |
Use the drop-down list to specify the font for double-byte characters. |